DC Circuit Breakerding Clip

DC Circuit Breakerding Clip

The JB is a DC circuit breaker dedicated to multi string photovoltaic installations.

JB is not polarity sensitive: (+) and (-) wires can inversed without any risk.

Compliance with standards: multi standard IEC 60947-2, EN60947-2, GB 14048.2


Technical Data:

Position contact indication – suitability for isolation according to IEC/EN 60947-2 standard.
The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety.
Increased product service life thanks to fast closing independent of the speed of actuation of the toggle
Pre-wired product: Input / Output on the same side.

Combined with a switch , the JB will be installed in a string PV protection enclosure at the end of each string of photovoltaic modules.

It can be locked (by a padlocking device) in OFF position as a safety measure for removal of the PV inverter.

Since a fault current can flow in the reverse direction to the operating current, the JB can detect and protect against any bidirectional current.

Main characteristics
Rated service breaking capacity (Ics)100 % of the Icu
Endurance (O-C)Electrical1,500 cycles (where L/R=2 ms)
Mechanical20,000 cycles
Mechanical20,000 cycles
Degree of pollution2
CategoryA (no delay in accordance with IEC / EN 60947-2 standards)
Degree of protection Device in modular (IEC 60529) enclosureIP40
TropicalisationRelative humidity: 95 % at 55°C in accordance with IEC 60068-2 and GB 14048.2 standards
TemperatureOperating-25°C to 70 °C
Storage-40°C to 85°C

Precautions

To ensure the safety of the installation, it is necessary, depending on the various types of application, to combine the JB with:

  • a residual current device at the AC end,
  • a fault passage detector (insulation monitoring device) at the DC end
  • an earth protection circuit breaker at the DC end

In all cases, fast action on site will be required to clear the fault (protection not ensured in the event of a double fault).

Main characteristics
Operating voltage (Ue)1P=250 V DC, 2P=500 V DC
3P=750 V DC, 4P=1000 V DC
Rated insulation voltage (Ui)1,000 V DC
Breaking capacity (Icu)10 kA
Impulse voltage (Uimp)4 kV
Electrical connectionBy the bottom for In and Out
Number of poles1P, 2P, 3P, 4P
StandardsIEC 60947-2
EN 60947-2